WASTEWATER TREATMENT FORMULA
(page 2)

INDIVIDUALIZED RATES AND METHODOLOGY

Due to inherent variances within each wastewater treatment facility Organica prefers to prescribe rates and methodology on an individual basis. These recommendations will be based on the characteristics and conditions of each system.

In order to accurately outline each plants requirements Organica requires the following information:

  1. A schematic diagram of the plant outlining flow
  2. Volume of each tank / lagoon within system
  3. Daily flow rate
  4. BOD, COD, pH and DO levels throughout system
  5. Retention time
  6. List of problems currently encountered


GENERALIZED RATES


Daily Waste Stream Volume Initial Dose Liquid Rate Initial Dose Dry Rate Maintenance Dose Liquid (DAILY) Maintenance Dose Dry (DAILY)
10,000 gal./38,000 liters 48 ounces/1.42 liters 1 lb/.46kg 24 ounces/.71 liters ½ lb/.23kg
10,000 gal./380,000 liters 1 gallon/38 liters 2.5 lbs/1.13kg 1/2 gallon/1.9 liters 1.25 lbs/.56kg
1,000,000 gal./3,800,000 liters 6 gallons/22.8 liters 15 lbs/6.8kg 3 gallons/11.4 liters 7.5 lbs/3.4kg


* DOUBLE THE INITIAL DOSE RATE WHEN STARTING BOD LEVELS ARE GREATER THAN 500, RETENTION TIME IS LESS THAN 48 HOURS OR WHEN SYSTEM'S WATER TEMPERATURES ARE BELOW50 DEGREES F.
* WHEN IMPLEMENTING THIS BIO - A UGMENTA TION PROGRAM IT IS ESSENTIAL TO PROVIDE THE MICROBIAL SYSTEMS WITH AS MUCH RETENTION TIME WITHIN THE SYSTEM AS POSSIBLE, IN ADDITION ADEQUATE DISSOLVED OXYGEN LEVELS (3 % or greater) WILL EXPEDITE THEIR ESTABLISHMENT AND INCREASE PRODUCT EFFICACY.
* SYSTEMS WITH A RETENTION TIME OF 24 HOURS OR LESS SHOULD UTILIZE THE LIQUID FORMULATION.
* ORGANICA MAY RECOMMEND THE ADDITION OF EACH ITS BIOCHEMICAL OXYGEN RELEASE SYSTEM IN ADDITION TO THE WASTEWATER FORMULATION. IT GREATLY INCREASES DISSOLVED OXYGEN LEVELS WITHIN SYSTEM AND DISCOURAGES ANAEROBIC GROWTH.

MICROBIAL SPECIFICATIONS

DRY FORMULA:
1,000,000,000 CFU PER GRAM OF PRODUCT. MICROBIAL COMPONENT IS IN SPORE / MICROENCAPSULATED VEGETATIVE STATE

LIQUID FORMULA:
100,000,000 CFU PER ML. MICROBIAL COMPONENT IS IN VEGETATIVE STATE