WASTEWATER TREATMENT TRIAL 1


The data below is the result of a trial done at a chemical wastewater treatment facility in India. This particular facility treated the wastewater generated by a pesticide production plant. The primary component of the waste stream was an array of "chlorinated hydrocarbons" generated during the pesticide production process. Chlorinated hydrocarbons are very difficult to biodegrade due to their complex structure.

Throughout the trial the BOD Levels (biological oxygen demand) were monitored on a daily basis. Biological oxygen demand is the amount of dissolved oxygen required to meet the metabolic needs of aerobic microorganisms in an aqueous environment rich in organic matter, such as sewage. In short BOD is a measure of the organic pollutant load. If BOD levels are reduced it is an indication that the microbial species present in the system are efficiently biodegrading / removing the organic pollutants within the system!

The purpose of this trial was to ascertain whether or not there was a correlation between applying Organica's Wastewater Treatment Product and the BOD levels present in the system. The data shows, that Organica's Wastewater Treatment Product has a profound affect on BOD levels. Furthermore the data shows that when less product, is added to the system the percentage of BOD reduction declined. It clearly demonstrates that when you inoculate wastewater with Organica's formulation it drastically increases the efficiency of the wastewater treatment process and expedites biodegradation. Again keeping in mind that the "chlorinated hydrocarbons" present in the system are difficult to degrade under any circumstance. The system utilized was very primitive, which further lends credence to the efficacy of the product. It consisted of an aeration tank (where effluent entered and product was applied) and a clarifying tank used to settle out solids (biomass). The flow rate was 26,400 gallons per day and the average dissolved oxygen reading in the aeration tank was 1.5 (a very low reading). Despite the fact that there were inherently low dissolved oxygen levels within the system the formulation still performed well. This lends credence to the facultative portion of Organica's formulation.

DAY INLET BOD OUTLET BOD % REDUCTION DOSAGE
1 3240 1170 73.9 % 3.3 Ibs
2 4330 920 78.8 % 3.3 Ibs
3 4560 903 80.2 % 3.3 Ibs
4 3640 860 76.4 % 3.3 Ibs
5 3595 840 76.7 % 3.3 Ibs
6 3900 872 77.7 % 3.3 Ibs
7 3690 940 74.6 % 3.3 Ibs
8 4390 776 82.4 % 3.3 Ibs
9 5400 976 82.0 % 3.3 Ibs
10 6320 910 85.7 % 3.3 Ibs
11 5290 1004 81.0% 3.3 Ibs
12 5807 1006 82.7 % 3.3 Ibs
13 3360 1084 67.8 % 55 Ibs
14 4910 1252 74.5 % 55 Ibs
15 4540 1426 68.6 % 55 Ibs
16 4375 1550 64.6 % 55 Ibs
17 3960 1610 59.4 % 55 Ibs
18 4720 1675 64.5 % 55 Ibs
19 4135 1860 55.0 % 55 Ibs
20 4156 1912 54.0 % 55 Ibs
21 3788 1877 50.5 % 55 Ibs